Use the CFT window to configure the ingress confirmation tone for a Signaling Profile.

To View and Edit CFT

On the SBC main screen, use one of the following paths:

  • Configuration > Profile Management > Category: Signaling Profiles > Signaling Profile > Ingress > CFT 
  • All > Profiles > Signaling > Signaling Profile > Ingress > CFT

Select a Signaling Profile from the drop-down list. The CFT window is displayed.

Signaling Profile - Ingress - CFT


Ingress CFT Parameters:

ParameterDescription
Send CFT Information

When this check box is selected for SIP calls, the egress SBC sends confirmation tone (CFT) information (whether the call is considered On-Net or Off-Net) to the SIP server. 

  • Disable (default)
  • Enable
Cft Info For Early Backward Message

Specifies the default value for the confirmation tone information when routes are absent from the policy response for SIP calls.

  • Offnet
  • Onnet
  • Unknown (default)

Note: This option appears when you enable Send CFT Information.