Type: CRITICAL

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.2.0.1

Description

This alarm indicates a server module redundancy switchover has occurred. The standby server module has become active.

The previous active server module and group information are included. For 1+1 the redundancy model, there is no group name.

Repetition

None

Event Codes

  • sonusCpSystemServerName
  • sonusCpRedundPrevActiveServerName
  • sonusCpRedundancyServicesGroupName

Instance Fields

None

Action

None

Impact

Loss of redundancy occurs for the particular redundancy group. Some transient calls may be lost due to switchover, but no lasting (normally) impact on overall system operation occurs.

Clearing

Manual