Specifies the parameters associated with Mfr1Detect.
To View and Edit Mfr1Detect
On SBC main screen, go to Configuration > Profile Management > Category: Digit Profiles > Digit Profiles > Mfr1Detect.
Select the desired Digit Profile from the drop-down list to view its respective Mfr1Detect parameters.
The Mfr1Detect window is displayed.
Profile Management - Digit Profiles - Mfr1Detect
The following fields are displayed:
Dtmf Mfr1Detect Parameters
Parameter | Description |
---|
Min Power | Specifies minimum power level in dBm required for digit detection. The value ranges from -45 to -25 dBm and the default value is -30. |
Min On Duration | Specifies minimum tone duration in milliseconds required for digit detection. The value must be increments of 5ms. The value ranges from 25 to 100 milliseconds and the default value is 25 milliseconds. |
Min Off Duration | Specifies minimum tone duration in milliseconds required for digit detection. The value must in increments of 5ms. The value ranges from 10 to 100 milliseconds and the default value is 15 milliseconds. |
Frequency Range | Specifies frequency tolerances for digit detection. The value represents accept and reject ranges. Frequencies detected within the accept range will result in digit detection. Frequencies detected outside the reject range will not result in digit detection. The options are: narrow (default)
medium wide wider
|
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.