Use this object to configure H.323 Signaling Ports.
Each signaling port within an Address Context must use a unique IP address and port number combination.
The SBC 7000 system supports creating IP Interface Groups containing sets of IP interfaces that are not "processor friendly" (i.e. carried on physical Ethernet ports served by separate processors). However, restrictions exist regarding the usage of such Interface Groups.
(This ability does not apply to the SBC 5400, which has only two physical media ports. You may configure the IP interfaces from the two physical ports within the same IP Interface Groups without restrictions.)
For complete details, refer to Configuring IP Interface Groups and Interfaces.
Command Syntax
% set addressContext <name> zone <name> h323SigPort <#> action <dryup | force> dryUpTimeout <0-1440> dscpValue <#> h225IpAddress <IPv4 address> h245IpAddress <IPv4 address> ipInterfaceGroupName <name> mode <inService | outOfService> portNumber <#> state <disabled | enabled>
// Mandatory parameters:
h323SigPort <index #> action <force | dryUp> dscpValue <0-63> h225IpAddress <ip address> ipInterfaceGroupName <name> mode <inService | outOfService> portNumber <1-65535> state <disabled | enabled>
// Non-mandatory parameters:
dryUpTimeout <0-1440> h245IpAddress <ip address>
Command Parameters