Sonus-provided SFP/SFP+ modules must be used to guarantee proper operation of the external ports. Failure to follow this recommendation may cause permanent damage to the system.

The 

Unable to show "metadata-from": No such page "_space_variables"
supports the following Small Form-factor Pluggable (SFP/SFP+) transceivers. SFPs (SFP/SFP+) are Customer Replaceable Units (CRU).

  • The following SFP transceivers are compatible with 

    Unable to show "metadata-from": No such page "_space_variables"
    Management ports:

    Transceiver TypeProduct CodeDescription
    CopperSBC-SFPCOPPER-1GGIGE, 1000 BASE-T SMALL FROM PLUGGABLE (SFP)
    Single-mode fiberSBC-SFPSM-1GGIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 10KM 1310NM, DMI
    Multi-mode fiberSBC-SFPMM-1GGIG-E, MULTIMODE, FIBER OPTIC TRANCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 300M
  • The following SFP+ transceivers are compatible with SBC 7000 series Media and HA ports:

    Transceiver TypeProduct CodeDescription
    Single-mode fiberSBC-SFPSM-10G10.3GB/S, SINGLE MODE, FIBER OPTIC XCVR, LC, SFP, 10KM 1310NM, DM
    Multi-mode fiberSBC-SFPMM-10G10.3GB/S, MULTIMODE, FIBER OPTIC XCVR, LC, SFP, 300M 850NM, DMI GIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE

Parts and Tools Required

The following items are needed to install/replace a SFP/SFP+ device:

  • Electrostatic discharge (ESD) strap
  • Replacement SFP/SFP+ transceivers.

To prevent damage from electrostatic discharge, an ESD strap is provided in the accessory kit. See Connecting Electrostatic Discharge Wrist Strap on SBC 7000 to install it.

Replacing the SFP/SFP+

To replace the SFP/SFP+:

  1. Attach an Electrostatic Discharge wrist strap by using the ESD grounding point on the back panel of the chassis. Follow the instructions in the section Connecting Electrostatic Discharge Wrist Strap on SBC 7000.
  2. Disconnect the fiber optic and/or Cat 5 cables, as appropriate, from media ports (Media 0-4) and HA ports (HA 0-1).
  3. Disengage the SFP/SFP+ transceiver from

    Unable to show "metadata-from": No such page "_space_variables"
    . The method used to disengage the SFP/SFP+ transceiver will vary according to the manufacturer. For example, hold the wire latch and move it downwards to the horizontal position and pull it outwards.

  4. Insert the Sonus-approved SFP/SFP+ transceiver into the desired socket and ensure that the latch mechanism engages.

  5. Reconnect the fiber optic and/or Cat 5 cables, as appropriate, to media and HA ports.
  6. Verify LEDs above the part are flashing indicating link status and data activity.
  7. Verify port functionality by using the application.

CRU Storage

All 

Unable to show "metadata-from": No such page "_space_variables"
CRUs are shipped in electrostatic discharge bags and should be handled using appropriate ESD precautions.

The storage environment for these CRUs are:

  • Humidity must be less than 95% (non-condensing).
  • Temperature must be between -40C and +70C.

 

The ESD Susceptibility symbol warns of the presence of Ribbon devices susceptible to electrostatic discharge. Do not handle equipment without wearing a properly grounded ESD wrist strap.