Overview

Use the signaling profile Called Prefix Match Profile to configure the prefix that the SBC matches against the called number. The prefix configuration is defined by the regex string pattern, start position of the string, and the digit length.

For information on other related profiles for SIP-ISUP and interworking between different SIP flavors, refer to Support for SIP-ISUP.

To View and Select Called Prefix Match Profile

On the SBC main screen, navigate to All > Profiles > Signaling > Called Prefix Match Profile.

The Called Prefix Match Profile window displays.

Called Prefix Match Profile

 


In the Called Prefix Match Profile List pane, select a profile using the radio button.

The Called Prefix Match Profile pane displays, showing the name of the selected profile.

Called prefix Match Profile - Selected


To Copy a Selected Called Prefix Match Profile

Select a profile from the Called Prefix Match Profile List pane, and click Copy Called Prefix Match Profile.

The Copy Selected Called Prefix Match Profile pane displays.

Copy Selected Called prefix Match Profile

 


Edit the fields in the pane, and click Save.

To Create a New Called Prefix Match Profile

Click +New Called Prefix Match Profile. The Create New Called Prefix Match Profile pane displays.

Create New Called prefix Match Profile

Called Prefix Match Profile - Field Descriptions

FieldLength/RangeDefaultDescriptionM/O
Name1-23 charactersN/A

The name of the Called Prefix Match Profile.

Note: You can configure a maximum of 10 Called Prefix Match Profiles.

M

 


Enter values for the fields displayed in the pane, and click Save.

To Delete a Selected Called Prefix Match Profile

Select a profile in the Called Prefix Match Profile List pane, and click the delete icon at the end of the selected row.

Confirm the delete prompt.

A success message displays.

Note

If the Called Prefix Match Profile is attached with a SIP Trunk Group, detach the profile before deletion.