This object allows you to configure SIP Peer Overload Control parameters.

To View and Edit Sip Peer Overload Control

On SBC main screen, go to All > Global >  Signaling > Sip Peer Overload Control.

The Sip Peer Overload Control window is displayed.

Global - Signaling - Sip Peer Overload Control


 

The following fields are displayed:

Sip Peer Overload Control

Parameter Description
Sampling Period
Specifies the sampling period (in seconds) for the Peer Overload backoff algorithm. The value ranges from 1 to 10 and the default value is 2 seconds.
Discard Period
Specifies the discard period (in seconds) for the Peer Overload backoff algorithm. The value ranges from 1 to 10 and the default value is 2 seconds.
Step Down Gain
Specifies the step down gain for the Peer Overload backoff algorithm. The value ranges from 1 to 200 and the default value is 100.
Reject Threshold
Specifies the reject threshold (in rejects/sec) for the Peer Overload backoff algorithm. The value ranges from 0 to 50 and the default value is 1.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.