Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.8.1.7.1.5.0.48

Description

This alarm indicates that the system is running out of memory and will soon reboot.

Repetition

None

Objects

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusNodeOverloadType
  • sonusNodeOverloadLevel
  • sonusNodeOverloadThresholdCurrent
  • sonusNodeOverloadThresholdConfigured
  • sonusAlarmNodeName
  • sonusAlarmPodName
  • sonusAlarmContainerName
  • sonusAlarmNsUuid
  • sonusAlarmCnfUuid
  • sonusAlarmCnfcUuid

Action

Check call/registration load and possible resource leakage.

Impact

Calls may get rejected.

Clearing

Automatic

  • sonusSystemNodeResourceClearCongestionWarningNotificationCnf

For SBC SWe, this alarm is also generated when there is a CPU congestion. Calls may get rejected during congestion in order to maintain system stability.

Note

If the node overload type mentioned in the alarm is "mem" then, the SBC application restarts only when the memory threshold of 90% is breached. If the node overload type is "XRM" in the alarm, then the SBC does not restart.