This screen helps you to understand retry counter values for various SIP request types.

To View and Edit Retry Counters

On the SBC main screen, navigate to All > Address Context > Zone > SIP Trunk Group > Signaling > Retry Counters.

The Retry Counters can be checked for each Address Context, for each Zone, for each SIP Trunk Group created or for all the Address Contexts, Zones and SIP Trunk Groups created. Use the drop-down box to select the desired Address Context, Zone and SIP Trunk Group.

The Edit Retry Counters window is displayed.

SIP Trunk Group - Signaling - Retry Counters

 

The following fields are displayed:

Sip Trunk Group - Signaling - Retry Counters parameters

Parameter

Length/Range

Description

General

4-12

Maximum number of retransmissions for generic SIP request. Default value is 7.

Invite

0-6Maximum number of retransmissions for SIP INVITE request. Default value is 6.

Bye

0-12Maximum number of retransmissions for SIP BYE request. Default value is 3.

Cancel

0-12

Maximum number of retransmissions for SIP CANCEL request. Default value is 3.

Re Invite

0-6

Maximum number of retransmissions for SIP Re-INVITE request. Default value is 3.

Retry On422

0-12

Maximum number of session keepalive negotiations upon receiving 422. Default value is 5.

Retry On491

0-12

Maximum number of session keepalive negotiations upon receiving 491. Default value is 5.

Invite200

0-10Maximum number of retransmissions for the 200 OK for initial SIP INVITE request. Default value is 0.