Reliability data for the Sonus SBC 1000 and SBC 2000 is provided below. Reliability data such as MTBF are non-binding estimates of product performance and is based on use of the products in compliance with related product data sheets, including, without limitation, within the specified electrical, thermal and mechanical parameters. Please consult your Sonus sales contact should you have any questions or would like additional information.
MTBF values were calculated according to Telcordia Technologies Special Report SR-332, Issue 1, May 2001 using Method II, (Black Box stress method integrated with laboratory data) including noted items below.
The tables below show the MTBF for each of the items used in the SBC 1000 and SBC 2000, as well as system MTBFs for several example configurations.
SBC Model | Description | MTBF in Years |
---|---|---|
SBC-2K-S-1 | Chassis + SBA + C900 DSP | 7.9 |
SBC-2K-2 | Chassis + 2x C900 DSP | 8.4 |
The following equation can be used to calculate the MTBF for different combinations of models and accessories:
Total MTBF = 1/ ((1/MTBF of Base System) + (1/MTBF of first desired accessory) + (1/MTBF of second desired accessory) ...)
Values on this page apply to pre-6.1 hardware. Sonus will post 6.1 values in the near future, please contact your Sonus representative if you have any questions.