You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

 

Use this object in a SBC ERE configuration to create Internal-to-SIP and SIP-to-Internal SIP Cause Mapping Profile names for this IP Signaling Profile.

SBC applies the Cause Code Mapping profile in the following order:

  1. If a policy response contains a profile name and a locally configured profile uses the same name, SBC applies the same name.

  2. If a policy response does not contain a profile name or if the profile name does not match with any local profile, SBC applies the SIP Trunk Group created local profile name (if created).

  3. SBC applies a default profile name if none of the above two cases match.

To View and Edit SIP Cause Mapping

On the SBC main screen, go to All > Profiles > Signaling > Ip Signaling Profile > Egress Ip Attributes > SIP Cause Mapping. The SIP Cause Mapping window is displayed.

DEFAULT_H323

On the SIP Cause Mapping window, choose Ip Signaling Profile as DEFAULT_H323 to view the SIP Cause Mapping parameters for H323 Trunk Group.

SIP Cause Mapping - H323

DEFAULT_SIP

On the SIP Cause Mapping window, choose Ip Signaling Profile as DEFAULT_SIP to view the SIP Cause Mapping parameters for SIP Trunk Group.

SIP Cause Mapping - SIP

The following fields are displayed:

SIP Cause Mapping - SIP

Parameter

Description

 Internal To SIP Cause Mapping Profile Name Specifies the name associated with Internal to SIP cause mapping profile.
 SIP To Internal Cause Mapping Profile Name Specifies the name associated with SIP to Internal cause mapping profile.

Make the required changes and click Save to save the changes made.

  • No labels