Specifies the details about Configuration related to signaling quality measured by  Sustained Call Rate Utilization (SCRU).

To View and Edit Scru

On SBC main screen, go to Configuration > System Provisioning > Security Configuration > Sip Cac Profile > QOE > Scru.

Select the desired Sip Cac Profile from the drop-down list to view its respective QOE - Scru parameters.

The Scru window is displayed.

Security Configuration - Sip Cac Profile - QOE - Scru

The following fields are displayed:

Scru Parameters

Parameter Description
Scru Critical LimitSpecifies the critical Sustained Call Rate Utilization (SCRU) limit, below which the call admission should be stopped. The value range from 80 - 100. The default value is 80.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 