In this section:
This object is used to configure Relay Port parameters.
On the SBC main screen, navigate to All > Address Context > Zone > Relay Port. The Relay Port can be checked for each Address Context and Zone or for all the Address Contexts and Zones created. Use the drop-down box to select the desired Address Context and Zone.
The Relay Port window is displayed.
Figure 1: Relay Port
To edit any of the Relay Port in the list, click the radio button next to the specific Relay Port name. The Edit Selected Relay Port window displays.
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.
To create a new Relay Port, click New Relay Port tab on the Relay Port List panel.
Figure 2: Relay Port Fields
The Create New Relay Port window is displayed.
Figure 3: Relay Port Create Window
The following fields are displayed:
Table 1: Relay Port Parameters
Parameter | Description |
---|---|
Index | The index of this Relay Port. Range 1-4000. Ensure each Relay Port index is unique across all zones. Up to 512 relay ports are configurable per zone, and up to 1,000 system-wide. |
Mode | The operational mode for this Relay Port. Options are:
|
State | The administrative state of the Relay Port.
|
IP Interface Group Name | IP interface group used by this Relay Port. |
Relay Profile | Enter the Relay Profile used by this Relay Port. |
IP Address V4 or V6 | The IPv4 or IPv6 address of the interface for this Relay Port. |
Port Number | TCP listener port number to use for this relay. Range is 1 to 65535. |
Transport Protocols Allowed | The transport protocol allowed on relay port. tcp is the only option in this release. |
To copy any of the created Relay Port and to make any minor changes, click the radio button next to the specific Relay Port to highlight the row.
Click Copy Relay Port tab on the Relay Port List panel.
The Copy Selected Relay Port window is displayed along with the field details which can be edited.
Make the required changes to the required fields and click Save to save the changes. The copied Relay Port is displayed at the bottom of the original Relay Port in the Relay Port List panel.
To delete any of the created Relay Port, click the radio button next to the specific Relay Port which you want to delete.
Click Delete at the end of the highlighted row. A delete confirmation message appears seeking your decision.
Click Yes to remove the specific Relay Port from the list.
Sub-system signaling ports (such as SIP signaling ports, relay ports, D-SBC signaling ports, H.323 signaling ports) must use different IP addresses because each IP address adds one system ACL, and IP addresses are not prioritized when measured in the same ACL. This best practice will avoid any IP addressing overlaps and ensure proper policing of packets.