DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.


NOTE:

  • If the error response is any of 401, 407, 408, and 7xx, the SBC exhibits the default characteristics even if the parameter is enabled.
  • When this parameter is disabled (as the default behavior), and the SBC gets error response for the REFRESH REGISTER, it changes the RCB state from REFRESHING to TERMINATED and starts a 64 second timer. If the SBC receives a Re-REGISTER request (REFRESH or UPDATE) within the next 64 seconds, it does not relay the request to the Registrar and locally responds to the UE with the previously preserved error message (because the RCB state is TERMINATED). However, if the SBC receives an Un-REGISTER request from the UE within the 64 seconds, it deletes the information about the earlier registration failures, and allows the next REGISTER attempt to go through.
  • When this parameter is enabled, on receiving an error response for REFRESH REGISTER attempts, the SBC sets the RCB state to COMPLETED instead of TERMINATED. On receiving subsequent REFRESH REGISTER requests, instead of locally relaying the previously stored error message to the UE, the SBC relays the REFRESH REGISTER request to the Registrar. In general, whenever the RCB is COMPLETED, the SBC relays the REFRESH REGISTER requests to the Registrar.