In this section:


Related articles:

Use the SIP JJ9030Interworking Profile window to configure SIP JJ9030 Interworking profiles which contain parameters needed for SIP JJ9030 Interworking. For information on other related profiles for SIP-ISUP and interworking between different SIP variants, refer to Support for SIP-ISUP.

To View SIP JJ9030 Interworking Profiles

On the SBC main screen, navigate to All > Profiles > Signaling > SIP JJ9030Interworking Profile

The SIP JJ9030Interworking Profile window opens.

SIP JJ9030Interworking Profile Window


To Create a SIP JJ9030 Interworking Profile

To create a new SIP JJ9030 Interworking Profile:

  1. Click New SIP JJ9030 Interworking Profile. The Create New SIP JJ9030Interworking Profile window opens.

    Create New SIP JJ9030Interworking Profile Window

  2. Use the following table to configure the parameters and then click Save.


SIP JJ9030 Interworking Profile Parameters

FieldLength/RangeDescription
Name1-23 characters

The name of this SIP JJ-90.30 Interworking Profile.

NOTE: You can configure a maximum of 32 SIP JJ9030 Interworking Profiles.

SIP FlavorN/A

The type of SIP parameters and procedures used for this interworking profile.

  • JJ9030
  • SIP-T
  • SIP-ttc-charging-params
Orig Ioi1-128 charactersThe name of the Originating Inter Operator Identifier.
Term Ioi1-128 charactersThe name of the Terminating Inter Operator Identifier.
Originating Carrier Code4 digits (0-9)

The Originating Carrier Code, consisting of 4 digits (0-9).

NOTE: This parameter is mandatory when the parameter SIP Flavor is set to JJ9030.

Terminating Carrier Code4 digits (0-9)

The Originating Carrier Code, consisting of 4 digits (0-9).

Modified: for 8.2.1

Charge Area Information5 digits (0-9)The Charge Area Information, consisting of 5 digits (0-9).
Add User Equal Phonefor Div Hi InterworkingN/A

Enable this parameter to add "user=phone" and the "mp" parameter for Diversion History Info Interworking.

  • Disabled (default)
  • Enabled
Set Hi Presentation RestrictedN/A

Set Presentation Indicator as "restricted" for History Info Interworking.

  • Disabled (default)
  • Enabled
BCI Charge IndicatorN/A

The Backwards Call Indicators Charge Indicator.

  • Charge
  • No Charge
  • No Indication
  • Spare

NOTE: This parameter is mandatory when the parameter SIP Flavor is set to SIP-ttc-charging-params.

BCI Called Party CategoryN/A

The Backwards Call Indicators Called Party Category.

  • No Indication
  • Ordinary
  • Payphone
  • Spare

NOTE: This parameter is mandatory when the parameter SIP Flavor is set to SIP-ttc-charging-params.

BCI Terminating ISDN AccessN/A

The Backwards Call Indicators Terminating ISDN Access Indicator.

  • Non ISDN
  • Isdn

NOTE: This parameter is mandatory when the parameter SIP Flavor is set to SIP-ttc-charging-params.


To Edit a SIP JJ9030 Interworking Profile

To edit a SIP JJ9030 Interworking Profile:

  1. Click the radio button adjacent to the name of the SIP JJ9030 Interworking Profile you want to edit. The Edit Selected SIP JJ9030 Interworking Profile window opens.
  2. Make any required changes to the profile and click Save.

To Copy a SIP JJ9030 Interworking Profile

To copy a SIP JJ9030 Interworking Profile:

  1. Click the radio button adjacent to the name of the  SIP JJ9030 Interworking Profile you want to copy.
  2. Click Copy SIP JJ9030 Interworking Profile. The Copy Selected SIP JJ9030 Interworking Profile window opens.
  3. Make any required changes to the profile and click Save.

To Delete a SIP JJ9030 Interworking Profile

To delete a SIP JJ9030 Interworking Profile:

  1. Click the radio button adjacent to the name of the  SIP JJ9030 Interworking Profile you want to delete.
  2. Click the delete icon (X) at the end of the row.
  3. Confirm the deletion when prompted.
Note

If a SIP JJ9030 Interworking Profile is associated with a SIP trunk group, remove it from the trunk group before deleting it.