DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.1.0.62

Description

This alarm is raised when a TCP connection to a particular monitoring server is not established after three failed attempts (IPV4).

Repetition

Yes

Event Codes

  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescriptin
  • sonusMonIpAddress
  • sonusMonPortNum

Instance Fields

  • sonusMonIpAddress
  • sonusMonPortNum

Action

Re-establish the TCP connection.

Note

Manually disable or enable the monitoring profile state after taking corrective actions.

Impact

The SBC cannot stream SIP PDUs to the monitoring server since the TCP connection is not established.

Clearing

Manual