DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

Type: CRITICAL

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.2.0.1

Description

This alarm indicates a server module redundancy switchover has occurred. The standby server module has become active. The previous active server module, and group information are included. For 1+1 the redundancy model, there is no group name.

Repetition

None

Event Codes

sonusCpSystemServerName
sonusCpRedundPrevActiveServerName
sonusCpRedundancyServicesGroupName

Instance Fields

None

Action

None

Impact

Loss of redundancy occurs for the particular redundancy group. Some transient calls may be lost as a result of switchover, but no lasting (normally) impact to overall system operation occurs.

Clearing

Automatic; sonusCpRedundGroupFullRedundancyNotification