Parameter Name | Required | Service Affecting | Data Type | Default Value | Possible Values | Description |
---|---|---|---|---|---|---|
ConfigIEState | No | Yes | Enum | 1 | Possible values:
| Enables or disables Auto Configuration. |
DeviceAccessURL | Yes | No | string | none | 512 - Max Length | Specifies the base URL for accessing files on the BroadSoft Server. |
EnableConfigUpdate | Yes | Yes | Enum | 0 | Possible values:
| Enables or disables the configuration update when SIP NOTIFY message is received from BroadSoft Server. |
EnableFirmwareUpdate | Yes | Yes | Enum | 0 | Possible values:
| Enables or disables the firmware update when SIP NOTIFY message is received from BroadSoft Server. |
EnableBootUpdate | Yes | Yes | Enum | 0 | Possible values:
| Enables or disables the firmware update when SIP NOTIFY message is received from BroadSoft Server. |
UserName | Yes | Yes | string | none | 128 - Max Length | User name to use for the BroadSoft server authentication. |
Password | Yes | Yes | string | none | 128 - Max Length | Password to use for the BroadSoft server authentication. |
autoConfigSG | Yes | Yes | int | 0 | Specifies the SIP Signaling Group ID used for receiving SIP NOTIFY messages from the BroadSoft Server. SIP Signaling Group ID can be obtained by performing a lookup on sipsg resource using GET sipsg |
The POST can contain either only the attributes that are being updated, or the full set of attributes for the resource