This object defines when to generate/clear an alarm for Ethernet CRC failures. A Major alarm (sonusSystemSecurityEthernetErrorNotification) is raised when the current Ethernet CRC rate is above the setThreshold value, and is cleared (sonusSystemSecurityEthernetClearNotification) once the error rate goes below the clearThreshold value. Refer to SBC Core Alarms Guide to know more about these two alarms (you can search for these alarms).

To View and Edit Ethernet Crc Err Alarm

On SBC main screen, go to All > OAM > Alarm > Ethernet Crc Err Alarm. The Ethernet Crc Err Alarm window is displayed.

OAM - Alarm - Ethernet Crc Err Alarm

 

The following fields are displayed:

OAM - Ethernet Crc Err Alarm parameter

 

Parameter

Description

Set Threshold

The threshold value to set this alarm. The value ranges from 0 to 2147483647 and the default value is 0.

A value of "0" disables the alarm.

Clear ThresholdThe threshold value to clear this alarm. The value ranges from 0 to 65535 and the default value is 100.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.