Use this object to specify the Packet Outage detection parameters for this GW Trunk Group.

To View and Edit Packet Outage

On the SBC main screen, navigate to All > Address Context > Zone > GW Trunk Group > Packet Outage.

The Packet Outage can be checked for each Address Context, Zone and GW Trunk Group or all the Address Contexts, Zones, and GW Trunk Groups created. Use the drop-down box to select the desired Address Context, Zone, and GW Trunk Group.

The Packet Outage window is displayed.


Packet Outage Parameters

Parameter

Length/Range

Description

Minimum Duration

0-65535The minimum outage (in milliseconds) on a call for that call to be counted as part of the packet outage detection algorithm. The default value is 6000.

Minimum Calls

0-65535The number of calls with outages required within the current interval to declare a packet outage event. The default value is 1000.

Bandwidth Limit Reduction

1-100The amount to reduce the bandwidth limit (as a percentage of the configured limit) when a packet outage is detected. The default value is 50.

Detection State

N/A

This flag enables automatic bandwidth reduction when a packet outage is detected.

  • Disabled (default)
  • Enabled

Detection Interval

5-1440

The size of the packet outage detection interval in minutes. The default value is 15.

Make the required changes and click Save.

  • No labels