DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

This is the global diameter profile containing elements that indicate whether Rf is enabled or not. The Diam Sig Controls profile contains the following elements:

  • Enable Rf App
  • Default CCF
  • Rf Interim Acc Inrvl
  • Generate Failed Event Acr
  • Max ACRretransmission

To View and Edit Diam Sig Controls

On SBC main screen, go to All > Global > Signaling > Diam Sig Controls. The Diam Sig Controls window is displayed.

Global - Signaling - Diam Sig Controls

 

 

The following fields are displayed:

Diam Sig Controls Parameters

 

Parameter

 Description

Enable Rf App

This parameter indicates whether Rf is enabled system wide. Based on this parameter, only normal CDR can be stopped. The options are:

  • enabled
  • disabled (default)
Default CCFThis parameter is used as CDF, if CCF is not received in the PCFA. By default, 0.0.0.0 is displayed.
Rf Interim Acc InrvlThis is over written if Accounting-Answer (ACA) has different value. 0 means no interim record is sent. The value ranges from 0 to 180 and the default value is 30.
Generate Failed Event Acr

If this parameter is enabled, no Accounting-Request (ACR) event for failed call can be sent. The options are:

  • enabled
  • disabled (default)
Max ACRetransmissionThis parameter supports maximum number of retransmission of ACR, if SBC does not receive ACA. The value ranges from 0 to 3 and the default value is 0.
Add Sonus Specific AVP

Enable flag to send additional CDR information within Sonus vendor-specific Attribute Value Pairs (AVPs) in Accounting-Request (ACR) messages over the existing Rf Interface.

  • Disabled (default)
  • Enabled

See Rf Interface Support for AVP details.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

  • No labels