Use the procedure below to upgrade the SBC 7000 Baseboard Management Controller (BMC) and BIOS firmware. The firmware images are bundled into a single package "firmware-7000-V<release>.img".
Windows and/or dialog boxes depicted in this section are intended as examples only and may not reflect the actual software/firmware versions applicable to you. Refer to your hardware/software requirements relevant release note for software/firmware version details.
Start
Logon to the SBC BMC GUI.
The BMC main screen displays defaulted to the Dashboard tab.
Click Firmware Update. The Firmware Update screen is displayed.
Click Choose File, and from the file explorer, browse to and select the "firmware-7000-V<release>.img" firmware image. To determine the exact firmware version, refer to SBC Release Information for the current release notes.
Click Upload.
The firmware image is approximately 26 MB and, depending on your network speed takes a few minutes to upload.
Once the upload is complete, the Firmware Update screen will display the uploaded firmware images and versions.
If both the Old Version and New Version are identical, the update status displays "No."
This service-affecting procedure will power off the host side of the SBC.
After you confirm, the BMC initiates an orderly shutdown of the host. If the process to shutdown the host fails, the upgrade fails. Take one of the following actions based on the current BMC version:
Once the upgrade is complete, the BMC and host will reboot automatically. Verify that the SBC starts and syncs with its peer before proceeding.
Log onto the SBC BMC GUI again.
The SBC BMC prompts you to change the password after a successful upgrade.
This change is applicable only when the BMC is upgraded to version 03.13.00 and later versions.
Click OK to proceed. The User Management window is displayed.
You have the option to cancel the action. If canceled, the password remains the same as the default password, and you are allowed to continue working on the BMC. However, the warning message is displayed again on your next login to BMC. This reminder continues until the password is changed. Refer to Changing the SBC 7000 BMC Password for the procedure to change the password.
For an HA configuration, refer to Upgrade Flows for guidance.