Level MC1 refers to limited congestion level. By default, no calls are rejected due to congestion in this level. The following are the set threshold and clear threshold percentages for Level MC1:

  • Set threshold: 85%
  • Clear threshold: 80%

On SBC main screen, go to All > System > Congestion > Level MC1.

The Level MC1 window is displayed.

System - Congestion - Adaptive

 

The following fields are displayed:

Level MC1 Parameters

Parameter

Description

Mode

The Maintenance mode of MC1.

  • inService (default)  – The most recently assigned Overload Profile is validated and activated.
  • outOfService – Congestion control processing for machine level 1 is suspended. A new Overload Profile can be assigned

Overload Profile Name

 The Overload Profile name of MC1.  

  • defaultMC1 (default)– The name of the Overload Profile assigned to Machine Congestion Level 1 (MC1). 
  • defaultMC2 – The name of the Overload Profile assigned to Machine Congestion Level 2 (MC2). 
  • defaultMC3 – The name of the Overload Profile assigned to Machine Congestion Level 3 (MC3).

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.