Not applicable to the SBC Software Edition (SWe).
Type: MAJOR
Object ID | 1.3.6.1.4.1.2879.2.8.1.4.1.1.0.1 |
Description | This alarm indicates the specified chassis power supply failed. |
Repetition | None |
Event Codes | sonusConnexIpSystemAdminName |
Instance Fields | None |
Action | Replace the power supply or source of power. Refer to the respective hardware installation guide for power supply replacement procedures. |
Impact | The server is running without power supply redundancy. If the second power supply fails during this time, the server will go down. |
Clearing | Automatic, sonusConnexIpSystemCEPowerSupplyNormalNotification |