The following procedure describes how to upgrade the BMC firmware from the BMC web GUI.
Log on to the SBC BMC using the following credentials:
Username: root
Password: superuser
On the BMC main screen, select the Remote Control tab. The Remote Control screen is displayed.
Click Power Control (or select Server Power Control option from the navigation pane). The Power Control and Status screen is displayed.
Select the Maintenance tab in the BMC GUI to enter the Maintenance screen.
If the power was not shut down successfully as described in step 4, the following pop-up message displays. Complete the step 4 before proceeding.
Click Enter Update Mode. The Update Mode confirmation dialog is displayed.
Click OK. The Firmware Upload screen displays.
Click Upload Firmware to upload the selected BMC image file.
An image verification dialog appears. Click OK to continue.
Verify that the Existing Version and New Version fields in Firmware Verification section are different. If the versions are different, continue to the next step to start the upgrade. Otherwise, click Cancel to exit out of the upgrade. A confirmation message appears on the screen. Click OK to continue. The Cancel operation reboots the BMC and host server as it must come out of the Maintenance mode.
Click Start Upgrade. When the warning dialog displays, click OK to continue.
The firmware upgrade process takes a few minutes to complete. The upgrade progress displays in the Flash Status screen.
Once the firmware upgrade completes, a confirmation screen appears.
Log on to the BMC GUI again and verify the upgraded version in the System Information page.
For HA configuration, see Upgrade Flows for guidance.