The SBC application upgrade from version 3.x/4.x to version 5.x or later is performed using Platform Manager. The ConnexIP Operating system and BIOS firmware is also upgraded along with the SBC application upgrade.
This procedure is service impacting.
The BIOS firmware upgrade is not part of SBC application upgrade in both SBC 7000 and SBC Software Edition platforms.
The following procedure describes the SBC Core application upgrade using the Platform Manager (non-LSWU):
Launch the Platform Manager.
The Platform Manager main screen appears.
Upload the SBC application package to the active and standby SBC servers using the Upload Files tab.
Click Upload Files.
Select the SBC application package files in the File Upload screen.
Click Open. The Files are added in the Upload Queue section.
Click Upload to upload the queued files.
Once the file upload is completed, the SBC application files are moved to the Files section.
Stop the application on the active server using Admin > Stop Application.
Stopping the application is a service-affecting operation. Confirm the stop operation by entering your user credentials and clicking Stop.
The application is stopped on the active server.
Launch the Platform Manager on the standby server.
Stop the application on the standby server using Admin > Stop Application.
Stopping the application is a service-affecting operation. Confirm the stop operation by entering your user credentials and clicking Stop.
The application is stopped on the standby server.
From the Platform Manager of the initial active server (WFDSBC01a), navigate to the SW Install > Upgrade SBC Application tab. Select the SBC Application Version to upgrade, and click Next.
Confirm the upgrade by providing your user credentials and clicking Upgrade.
The upgrade process starts on the active server (WFDSBC01a) and displays the upgrade status on the View Application Upgrade Log screen.
Once the upgrade is successful, clear the browser cache prior to accessing the SBC EMA.
Launch the EMA Platform Mode.
Log on using the default credentials.
Verify the SBC application status on the Administration > System Administration > Platform Management screen.
Follow step 12 through step 16 to perform the upgrade on the standby server (WFDSBC01b).
Verify the standby SBC application status on the Administration > System Administration > Platform Management screen.
Verify the firmware, ConnexIP OS and SBC application versions in Monitoring > Dashboard > System and Software Info.
Log on to EMA. Navigate to Monitoring > Dashboard > System Status to verify the overall HA system status on the active server.