In this section:
Use this window to work with CPC-to-SIP cause mapping profiles on the node. These profiles can be assigned to SIP trunk groups and map internal CPC (Call Processing Component) cause codes to SIP status codes.The SBC provides four mapping profiles by default that you can assign to trunk groups. The default profiles cannot be modified or deleted. However, you can create custom mapping profiles which you can assign to trunk groups.
The SBC supports SIP Cause Code Mapping for CPC to SIP for trunk groups regardless of the signaling zone. For more information, refer to SIP Profiles.
SBC Core supports up to 64 SIP-to-CPC and 64 CPC-to-SIP cause code mapping profiles.
On the SBC main screen, go to Configuration > Profile Management > Category: Signaling Profiles > SIP Cause Code Mapping > CPC To SIP Cause Map Profile or
All > Profiles > Signaling > SIP Cause Code Mapping > CPC To SIP Cause Map Profile
The CPC To SIP Cause Map Profile window opens.
To create a new CPC To SIP cause map profile:
Click New CPC To SIP Cause Map Profile. The Create New CPC To SIP Cause Map Profile window opens.
The specific CPC to SIP code mappings within the profile are created on the Cause Map window. Refer to CPC To SIP Cause Map Profile - Cause Map.
The default profiles cannot be edited. To edit a CPC To SIP cause map profile you added:
The default profiles cannot be deleted. To delete any of the CPC To SIP cause map profile you added: