Specifies the details about Refer policer.


Note

 The SBC supports up to 100 call transfers for a call.

To View and Edit Refer

On SBC main screen, go to Configuration > System Provisioning > Security Configuration > Sip Cac Profile > Refer.

Select the desired Sip Cac Profile from the drop-down list to view its respective Refer parameters.

The Refer window is displayed.

Security Configuration - Sip Cac Profile - Refer

 

The following fields are displayed:

Refer Parameters

Parameter

Description

Ingress Aggregate Preference

Specifies the preference for REFER within the ingress aggregate policer. The value range from 1 - 10. The default value is 1.

Ingress Burst Size

Specifies the maximum burst size for ingress REFER. The value range from 1 - 10000. The default value is 1.

Ingress Rate

Specifies the maximum ingress REFER rate in REFER per period. The value range from 1 - 1000 or unlimited.

Ingress Rate Period

Specifies the time period (in seconds) over which ingress REFER rate applies. The value range from 1 - 10 seconds. The default value is 1 second.

Egress Aggregate Preference

Specifies the preference for REFER within the egress aggregate policer. The value range from 1 - 10. The default value is 1.

Egress Burst Size

Specifies the maximum burst size for egress REFER. The value range from 1 - 1000. The default value is 1.

Egress Rate

Specifies the maximum egress REFER rate in REFER per period. The value range from 1 - 1000 or unlimited.

Egress Rate Period

Specifies the time period (in seconds) over which egress REFER rate applies. The value range from 1 - 10 seconds. The default value is 1 second.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 