In this Section:
Visual First Call Setup is not available for SBC Cloud environments.
Visual First Call Setup is an EMA based tool that guides you through the procedure of configuring the SBC for processing calls in an experimental setup.
Use the Visual First Call Setup tool to configure the SBC for processing low volume of calls. The most typical use case is testing a new feature of the SBC in an experimental/laboratory set up, under light to moderate levels of traffic. Sonus recommends using other standard procedures for configuring SBCs for production deployments.
The Visual First Call Setup tool is a guided procedure - it maintains the order of actions that needs to be performed. You are not allowed to skip one or more actions (forward or backward).
Visual First Call Setup offers limited functionality in terms of real-time update of the configuration status of the objects. If you configure an object using this tool, and then delete the configuration through EMA or CLI, the tool still reflects the configuration status as "configured", and displays the circular green button adjacent to the object instead of red.
On the SBC main screen, navigate to Configuration > Configuration Wizards > Visual First Call Setup.
The Visual First Call Setup window is displayed.
Visual First Call Setup - View as Diagram
The banner Provision the SBC for Basic SIP Peering (at the top of the Visual First Call Setup window) displays information on the preliminaries of the configuration procedure.
Provision the SBC for Basic SIP Peering
There are two options to view the entire consolidated configuration:
View as Diagram
(default)View as Table
View as Diagram/Table
To see the consolidated configuration in tabular form, select View as Table:
Visual First Call Setup - View as Table
The gear icon
is not displayed when the configuration is viewed as a table. The tabular presentation is suitable for viewing the configuration, but to configure the SBC using the Visual First Call Setup tool, switch to View as Diagram.If the SBC is not configured using the Visual First Call Setup tool, as in case of a freshly installed/upgraded SBC:
When viewed as diagram, instead of a green circle, a red circle is displayed beside each configuration element. For more information, see Provision the SBC for Basic SIP Peering.
(Not Configured) Visual First Call Setup - View as Diagram
Except Customer Network > PBX and Carrier Network > Carrier, all other configuration elements remain inactive; this is to ensure that the sequence of the configuration is maintained.
When viewed as table, the table is displayed only with fields but no values.
(Not Configured) Visual First Call Setup - View as Table
Follow the Configuration Elements Hierarchy to configure the elements displayed in the Visual First Call Setup window.
Customer Network
PBX
Carrier Network
Carrier
<CE Name>
Internal/Core/Trusted Side
IP Interface Group
IP Interface
Static Route
Zone
SIP Trunk Group
SIP Signaling Port
IP Peer
External/Carrier/Untrusted Side
IP Interface Group
IP Interface
Static Route
Zone
SIP Trunk Group
SIP Signaling Port
IP Peer
Routing
Click the gear icon adjacent to Customer Network > PBX.
PBX
The Edit PBX dialog box is displayed.
Edit PBX
Enter values in the fields and click Save. To restore the fields to defaults, click Cancel.
Click the gear icon adjacent to Carrier Network > Carrier.
Carrier
The Edit Carrier dialog box is displayed.
Edit Carrier
Enter values in the fields and click Save. To restore the fields to defaults, click Cancel.
Click the gear icon adjacent to IP Interface Group.
IP Interface Group
The Edit IP Interface Group dialog box is displayed.
Edit IP Interface Group
Click the gear icon adjacent to IP Interface.
IP Interface
The Edit Media IP Interface dialog box is displayed.
Edit Media IP Interface
Click the gear icon adjacent to Static Route.
Static Route
The Edit Static Route dialog box is displayed.
Edit Static Route
Click the gear icon adjacent to Zone.
Zone
The Edit Zone dialog box is displayed.
Edit Zone
Click the gear icon adjacent to SIP Trunk Group.
SIP Trunk Group
The Edit SIP Trunk Group dialog box is displayed.
Edit SIP Trunk Group
Click the gear icon adjacent to SIP Signaling Port.
SIP Signaling Port
The Edit SIP Signaling Port dialog box is displayed.
Edit SIP Signaling Port
Click the gear icon adjacent to IP Peer.
IP Peer
The Edit IP Peer dialog box is displayed.
Edit IP Peer
Click the gear icon adjacent to IP Interface Group.
IP Interface Group
The Edit IP Interface Group dialog box is displayed.
Edit IP Interface Group
Click the gear icon adjacent to Media IP Interface.
Media IP Interface
The Edit Media IP Interface dialog box is displayed.
Edit Media IP Interface
Enter values in the fields and click Save. To restore the fields to defaults, click Cancel.
While configuring various elements of the Visual First Call Setup tool, you may encounter error messages of two types:
Port Name
as pkt0
(displayed on the Edit Media IP Interface window) for both Internal (PBX) as well as External (Carrier) side of the setup, an error message is generated from the back-end and displayed on your browser.Click the gear icon adjacent to Static Route.
Static Route
The Edit Static Route dialog box is displayed.
Edit Static Route
Click the gear icon adjacent to Zone.
Zone
The Edit Zone dialog box is displayed.
Edit Zone
Click the gear icon adjacent to SIP Trunk Group.
SIP Trunk Group
The Edit SIP Trunk Group dialog box is displayed.
Edit SIP Trunk Group
Click the gear icon adjacent to SIP Signaling Port.
SIP Signaling Port
The Edit SIP Signaling Port dialog box is displayed.
Edit SIP Signaling Port
Click the gear icon adjacent to IP Peer.
IP Peer
The Edit IP Peer dialog box is displayed.
Edit IP Peer
Click the gear icon adjacent to Routing.
IP Peer
The Edit Routing dialog box is displayed.
Edit Routing