DO NOT SHARE THESE DOCS WITH CUSTOMERS!
This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.
Type: CRITICAL
Object ID | 1.3.6.1.4.1.2879.2.10.1.1.14.0.1 |
Description | This alarm is generated when either pass-through or transcoded sessions fail to set up due to the lack of a valid session license, or if the total number of active sessions has reached the session license limit. As a result, new calls will fail. |
Repetition | None |
Event Codes | sonusAlarmNodeID |
Instance Fields | sonusSessLicenseLimit |
Action | Obtain additional session licenses. |
Impact | Calls exceeding the session license limit are rejected. |
Clearing | Automatic; sonusSbxCallRejectsDueToSessionLicenseClearNotification |