At least seven days prior to starting the upgrade, complete the following tasks.
Refer to
.If other Ribbon Core elements are integrated with the SBC, ensure they are running a version compatible with the target SBC load according to
.Examine all Warnings/Bulletins/Announcements listed in the "Associated Ribbon Announcements" section for the target release
to verify they are applicable to the upgrade path in the Ribbon support portal. Log on to the to view WBA details.In addition to the Warnings/Bulletins/Announcements listed in the Release Notes, log on to the Ribbon support portal and verify all Warnings/Bulletins applicable to the upgrade path.
Review RNs for the SBC configuration requirements to implement prior to the upgrade.
Some examples are SWe HW configuration requirements and memory requirements for SBC 51xx and 52xx systems, depending on target release and username requirements.
chmod 777 /opt/sonus/external/sbc-V*
Call arrival rate limits are enforced during upgrade.
Verify the system call arrival rate (systemCongestionCallArrivalRate) using the following CLI command. The maximum call rate allowed for Live Software Upgrade (LSWU) differs between various SBC platforms.
For more information, refer to
.Example:admin@WFDSBC01a> show status system systemCongestionStatus
systemCongestionStatus entry {
systemCongestionMCLevel 0;
systemCongestionCPULevel 0;
systemCongestionMemLevel 0;
systemCongestionCallRateLevel 0;
systemCongestionMCDuration 67397;
systemCongestionCallArrivalRate 355;
systemCongestionCallAcceptRate 100;
systemCongestionCallAcceptCount 0;
systemCongestionCallEqArrivalRate 355;
systemCongestionRegArrivalRate 0;
systemCongestionIRTTLevel 0;
}
Ensure that no Critical/Major alarms are present prior to the upgrade, unless they are confirmed as non-impacting.
To check alarms via EMA:
Log in to the EMA on the active server, and navigate to: Monitoring -> Dashboard -> Alarms -> Current alarms.
For earlier versions of EMA (4.x):
Login to EMA on the active server, and navigate to: Troubleshoot -> Alarms -> Current.
To check alarms via CLI:% show table alarms currentStatus
For upgrades to 05.xx.xx:
Refer to Hard disk usage requirements for upgrading to version 05.xx.xx.
For upgrades to 06.xx.xx or higher releases:
Maximum of 70% used and at least 3G free space on '/' partition
Maximum of 80% used and at least 7G free space on '/home' partition
Maximum of 70% used and at least 7G free space on '/dev/drbd0' partition (active node only)
The automated pre-check covers this step.
To check for disk space, run df -k -h -P.
This step is applicable ONLY for hardware SBCs.
To check for disk speed, run hdparm -t --direct rootDisk.
Example:
[root@example.com ~]# hdparm -t --direct /dev/sda /dev/sda: Timing O_DIRECT disk reads: 584 MB in 3.01 seconds = 193.85 MB/sec [root@eruditorum.org ~]#
To obtain the root disk, perform the following command as root
:
cat /proc/partitions 2> /dev/null | awk '$2 == 0 { print $NF }' | grep -Ev "dm-0|sr0|drbd0|fd0"
The rootDisk partition is /dev/
followed by the output of the command above.
SSD minimum speed is 100 MB/s. The upgrade will abort and fail if SSD speed falls below this threshold.
The automated pre-check covers this step.
Use the "show table system serverStatus" CLI command, and confirm "MGMT REDUNDANCY ROLE" shows active/standby:
Example (shortened for brevity):
admin@LABNBS2A> show table system serverStatus MGMT PLATFORM APPLICATION REDUNDANCY APPLICATION UP LAST RESTART NAME HW TYPE SERIAL NUM PART NUM VERSION VERSION ROLE UP TIME TIME REASON SYNC STATUS ------------------------------------------------------------------------------------------------------------------------------------------------------ LABNBS2A SBC 5200 2038100494 821-00430 V06.02.03R000 V06.02.03R000 active 21 Days 21:59:38 21 Days 21:50:18 systemRestart syncCompleted LABNBS2B SBC 5200 4031110016 821-00430 V06.02.03R000 V06.02.03R000 standby 10 Days 00:14:02 10 Days 00:12:00 systemRestart syncCompleted
The automated pre-check covers this step.
Use the "show table system syncStatus" CLI command.
Example for HA systems:
admin@LABNBS2A> show table system syncStatus SYNC MODULE STATUS --------------------------------------- Policy Data syncCompleted Disk Mirroring syncCompleted Configuration Data syncCompleted Call/Registration Data syncCompleted
Example for Standalone systems:
admin@LABSTD> show table system syncStatus SYNC MODULE STATUS ------------------------------------- Policy Data unprotected Disk Mirroring unprotected Configuration Data unprotected Call/Registration Data unprotected
Use the show table system ethernetPort mgmtPortStatus
CLI command:
Example:
admin@LABNBS2A> show table system ethernetPort mgmtPortStatus PORT IF RX TX RX TX RX TX CE NAME NAME INDEX MAC ADDRESS LINK STATE PACKETS PACKETS ERRORS ERRORS DROPPED DROPPED ------------------------------------------------------------------------------------------------------------------- LABNBS2A mgt0 1 0:10:6b:2e:e7:91 admnEnabledPortUp 27189224 2115956 0 0 0 0 LABNBS2A mgt1 2 0:10:6b:2e:e7:92 admnEnabledPortUp 7474875 45345 0 0 0 0 LABNBS2B mgt0 3 0:10:6b:2:ee:76 admnEnabledPortUp 34677 354 0 0 0 0 LABNBS2B mgt1 4 0:10:6b:2:ee:77 admnEnabledPortUp 35362 425 0 0 0 0
The steps to accomplish this check are included in .
Check how many days the SBCs are up ('UP TIME') using the following CLI command.
Example (shortened for brevity):
admin@SWE1> show table system serverStatus MGMT PART PLATFORM APPLICATION REDUNDANCY APPLICATION UP NAME HW TYPE SERIAL NUM NUM VERSION VERSION ROLE UP TIME TIME -------------------------------------------------------------------------------------------------------------------------------------------- SWE1 Sonus SBC SWe 15AF4D56-2731-4822-F9AA-BBCCDD62C816 - V06.01.00R001 V06.01.00R001 active 9 Days 00:14:03 9 Days 00:11:56 SWE2 Sonus SBC SWe 4F874D56-1403-209B-E224-1D84F5C99A7C - V06.01.00R001 V06.01.00R001 standby 9 Days 00:11:09 9 Days 00:07:01
If the SBCs are up for more than 200 days, reboot the servers prior to upgrade. Reboot the standby SBC first. Then once the SBCs are back in sync again, switchover the SBC application and reboot the new standby SBC.
14.2.1. SSH to the SBC associated to the standby BMC as root user and ensure is standby:
sbxstatus | grep 'Service running'
** Service running [standby] **
14.2.2. Stop the server on standby SBC, as root user:
sbxstop
14.2.3. Power off the server via BMC GUI:
Remote Control -> Server Power Control -> Power Off Server - Orderly Shutdown -> Perform Action
14.2.4. Ensure after Orderly Shutdown, server is showing 'Host is currently off' on BMC:
BMC Remote Control -> Server Power Control ("Power Control" in 2.x BMC versions) window
14.2.5. ssh to the BMC and verify that the SBC is powered off by running the following command.
For BMC versions 2.x and higher, enable ssh access in BMC GUI > Configuration > Network ("BMC Network" in 2.x BMC versions):
ipmitool -H127.0.0.1 -Uroot -Psuperuser power status
The output of the above command should read "Chassis Power is off".
If your BMC ssh root password is not default, change the '-P' parameter value in the above command, accordingly.
14.2.6. Reboot the BMC:
For BMC versions 2.x, reboot the BMC via the GUI: Maintenance -> Reboot BMC.
For other BMC versions, run "reboot" command on the BMC ssh session.
14.2.7. The BMC will come back after 2 minutes and the system will boot back to standby mode.
Ensure the following:
- Access to the BMC GUI and remote console is successful (prompt is available)
- The SBC is back at standby.
- The SBCs are in sync (show table system syncStatus
via CLI)
14.2.8. Switchover the SBC application and repeat steps 13B.1 - 13B.7 to the newly standby SBC / BMC.
The automated pre-check covers this step.
/opt/sonus/conf/sbx.conf file
./opt/sonus/sbx.conf
Example (shortened for brevity):
[root@LABNBS2A ~]# cat /opt/sonus/conf/sbx.conf # SBX startup configuration. # # Copyright (c) 2010 Sonus Networks, Inc. # All rights reserved. # # Configuration generated by sbxInit.sh: # Thu Oct 31 15:59:03 CET 2019 role=1 # 1=Active, 2=Standby systemName=LABNBS2 ceName=LABNBS2A peerCeName=LABNBS2B
This step is only applicable for HA setup. You can use it for offline upgrade as well.
LSWU pre-checks using the Upgrade Manager interface do not affect any ongoing SBC services.
Prior to performing LSWU pre-checks using the Upgrade Manager interface, ensure:
To perform LSWU pre-checks:
In the Packages panel, select the package that you want to upgrade to.
Click Live Software Upgrade to continue with the LSWU pre-checks. The SBC validates the selected package.
Once the package is verified, the SBC displays the upgrade option.
Click Perform Pre-Upgrade Checks.
You can perform pre-upgrade checks anytime, including outside the maintenance window. These checks verify if the system is ready for an upgrade.
A Pre-Upgrade Checks Complete message is displayed after the verification is complete or error messages are displayed if there are pre-check failures. Ensure to resolve the errors and repeat the pre-upgrade checks to confirm these are successful prior to the actual upgrade start.
After the pre-checks are run, press Cancel to abort the actual upgrade process.