Tone tables allow the
A maximum of eight Tone Tables is permitted in the system.
For
Do not configure a ringback or congestion tone with frequencies greater than 1KHz when also setting for "continuous" (as opposed to Cadence).
To create or modify an Entry to a Tone Table:
- In the WebUI, click the Settings tab.
In the left navigation pane, click Tone Tables > Default Tone Table.
Default Tone Table (SBC 1000 / 2000)
Default Tone Table (SBC SWe Edge)Click the expand ( ) icon.
Tone Tables - Field Definitions
Frequency 1 and Frequency 2
Specifies the frequency in Hertz.
Frequency 2 is optional
Amplitude 1 and Amplitude 2
Specifies the amplitude in decibels per milliwatt (dBm) for Frequency 1 and Frequency 2.
Amplitude 2 is available only when Configure Frequency 2 is set to Yes.
Continuous Tone
Specifies whether to use a continuous tone or a cadence.
Cadence On
Specifies the duration of time, in milliseconds, that the tone is on. Available only when Continuous Tone is set to Cadence.
Also applies in the Double Cadence pane.
Cadence Off
Specifies the duration of time, in milliseconds, that the tone is off. Available only when Continuous Tone is set to Cadence.
Also applies in the Double Cadence pane.
Double Cadence
Specifies that the tone is used in a double cadence form.
This only applies to POTS fixed phones, where the high voltage ring signal is switched on and off to create the ringing pattern. In North America, the standard ring cadence is "2-4", or 2000 ms followed by 4000 ms of silence (default