REST API Method: POST /rest/enmsignalingprofile/{identifier}

Modifies a CAS E and M Signaling Profile given a specific ID.

Note

The CAS E and M Signaling Profile identifier can only be within the range 10001-15000 (inclusive)

URL:

https://192.168.0.111/rest/enmsignalingprofile/{identifier}

HTTP Method

POST

Requires Authentication:

true

The root page @parent could not be found in space SBC 1000/2000 API.

Parameters

Parameter Name Required Service Affecting Data Type Default Value Possible Values Description
DescriptionNoNostringnone64 - Max Length A description of the profile.
OrientationYesNoEnum0Possible values:
  • 0 - eCas_User
  • 1 - eCas_Network
Set the CAS signaling orientation. Set to User if connected to a PSTN; Set to Network if connected to a PBX.
IncomingStartDialYesNoEnum0Possible values:
  • 0 - eCas_EmWinkStart
  • 1 - eCas_EmImmediateDialing
Used to configure the type of E&M protocol for incoming calls.
OutgoingStartDialYesNoEnum0Possible values:
  • 0 - eCas_EmWinkStart
  • 1 - eCas_EmImmediateDialing
Used to configure the type of E&M protocol for outgoing calls.
DTMFOnTimeYesNoint100Possible values:
  • 45 - Minimum
  • 250 - Maximum
Used to set how long DTMF tones are on. The value specifies the time in milliseconds.
DTMFOffTimeYesNoint100Possible values:
  • 45 - Minimum
  • 250 - Maximum
Used to set how long DTMF tones are off. The value specifies the time in milliseconds.
InterDigitTimeoutYesNoint500Possible values:
  • 250 - Minimum
  • 30000 - Maximum
Used to set the timeout time between dialed numbers. The value specifies the timeout period in milliseconds.

Helpful Tip

The POST can contain either only the attributes that are being updated, or the full set of attributes for the resource