Use the following procedure to recover the SBC SWe HA on public cloud after reverting to a pre-11.0 release if the SBC application does not come up on both the active and standby nodes. This procedure is only applicable if the system is upgraded from a pre-11.0 release to this release using the following method: Once complete, check to see if application is coming up fine on both active and standby nodes. If present, remove the following file/directories from both the active and standby SBC: Check to make sure that the application starts up on both nodes. If you are using the RAF for upgrade/revert, perform the steps 1.3 to 3.1 within 30 minutes after running the revert operation. This ensures that the RAF can detect the correct state of VNF and mark the operation as complete.Step Action 1
command sbxstop
.2 rm -rf /home/cnxipmadmin/peerDynamicHANewComps
rm -rf /opt/sonus/sbx/openclovis/var
3 sbxstart
’ command.