Not applicable to SBC SWe Edge.


Table of Contents
About this Page
  • This Interoperability Note describes how to configure a TDM port on a Mitel 3000 ICP PBX to integrate with the Ribbon SBC Edge Portfolio.  Also included is configuration information for integrating Exchange Unified Messaging to the Mitel PBX via SBC Edge Portfolio.
Related Articles

Prerequisites

Requires Ribbon SBC Edge Portfolio Version 3.0

Mitel 3300 ICP PBX, Version 9.0.0.41, T1, QSIG

Interoperation Notes

The following extension numbers are used within this document:

•  UMS Pilot Extension: 2562
•  Extensions enabled for Microsoft Exchange Server UM: 5100 - 5199

PBX Configuration

Use the following configurations to interconnect the Mitel to SBC Edge Portfolio.

  1. Ensure that your Mitel 3300 ICP PBX has the necessary T1 PRI Module to Support T1 QSIG by navigating to: System Configuration / Units/Modules / Units Configuration Display.

    Unit Configuration Display

    Dual T1/E1 Framer Configuration

    Dual T1/E1 Framer Port Configuration



  2. Create Class of Service for your QSIG trunk by using the following path to create a Class of Service for the QSIG trunk: System Configuration / Trunks / Class of Service Options Assignment.

    Class of Service Options 1

  3. Create a Link Descriptor Assignment by using the following path: System Configuration / Trunks / Digital Trunks / ISDN-PRI / Link Descriptor Assignment.

    Link Descriptor Assignment



  4. Create a Digital Link Assignment by using the following path: System Configuration / Trunks / Digital Trunks / ISDN-PRI / Digital Link Assignment.

    Create Digital Link Assignment

  5. Add a MSDN-DPNSS-DASSII Trunk Circuit Descriptor by using the following path: System Configuration / Trunks / Digital Trunks / ISDN-PRI/MSDN-DPNSS-DASSII Trunk Circuit Descriptor.

    Create MSDN-DPNSS-DASSII Trunk Circuit Descriptor


  6. Create a Trunk Service Assignment by using the following path to create a Trunk Service Assignment: System Configuration / Trunks / Digital Trunks / ISDN-PRI / Trunk Service Assignment.

    Create Trunk Service Assignment


  7. Assign Digital Trunks by using the following path to assign Digital Trunks: System Configuration / Trunks / Digital Trunks / ISDN-PRI / Digital Trunk Assignment.

    Digital Trunk Assignment Form

  8. Add a Trunk Group for QSIG Using the following path: System Administration / Automatic Route Selection / Trunk Group Assignment. Next, create a new trunk group for QSIG and add trunk group members.

    Trunk Group Members Form


  9. Add a Route Assignment by using the following path: System Administration / Automatic Route Selection / Route Assignment.

    Add Route Assignment



  10. Add a ARS Digits Dialed Assignment by using the following path to add ARS Digits Dialed Assignment: System Administration / Automatic Route Selection / ARS Digits Dialed Assignment.

    ARS Digits Dialed Assignment Form


  11. Under System Option Assignment, set the following fields as follows:
     
    1) Route Optimization Network ID: Select a unique number.
    2) DPNSS/QSIG Diversion Enabled: Select 'Yes'.



  12. Use the TDM document to configure SBC Edge Portfolio.

    •  Configuring TDM ports on SBC Edge Portfolio