DO NOT SHARE THESE DOCS WITH CUSTOMERS!
This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.
The Daughter Board Admin table resides at the Server/CE level as opposed to System/Global level so the user can perform activities on a Standby server without impacting the active Server/Sessions.
% set system daughterBoardAdmin <system name> <slot 1-4> disableCleanupType <forced | graceful> dryupTime <0-60 minutes> state <disabled | enabled>
Parameter | Range/Length | Description |
---|---|---|
<slot number> | 1-4 | The slot associated with the DSP2x card. |
disableCleanupType | N/A | The type of cleanup action to take when disabling the DSP card.
|
dryupTime | 0-60 | The amount of time, in minutes, to perform the cleanup action. (default = 10) This setting only applies when the A dryup limit of "0" allows the system to wait indefinitely for the dryup to complete.
|
state | N/A | Administrative state of the DSP card.
|