DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

This object is used to understand the SILC traffic control for the specified Gw Trunk Group.

To View and Edit Silc

On SBC main screen, navigate to All > Address Context > Zone > Gw Trunk Group > Call Reservation > Silc.

The Silc can be checked for each Address Context, Zone, and Gw Trunk Group or for all the Address Contexts, Zones, and Gw Trunk Groups created. Use the drop-down box to select the desired Address context, Zone, and Gw Trunk Group.

The Silc window is displayed.

All - Address Context - Zone - Gw Trunk Group - Call Reservation - Silc

The following fields are displayed:

SILC Parameters

ParameterDescription

State

The Administrative state of the SILC traffic control. Select any one of the option:

  • disabled (default)
  • enabled

MC1Percent

The percentage of calls to accept when the machine congestion level is 1. Enter value in range of 0-100 percent. Default is 75.

MC2Percent

The percentage of calls to accept when the machine congestion level is 2. Enter value in range of 0-100 percent. Default is 25.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 

  • No labels