This object allows you to configure the signaling timers for the gateway.

To View and Edit Gw Sig Timers

On SBC main screen, go to Configuration > Profile Management > Category: Signaling Timers > Gw Sig Timers.

The Gw Sig Timers window is displayed.

Profile Management - Signaling Timers - Gw Sig Timers

The following fields are displayed:

Gw Sig Timers parameters

Parameter Description
EstablishSpecifies the Gateway Signal Channel Establishment Timer (in seconds.) This value applies to all signal channels. The value ranges from 1 to 65535 and the default value is 10 seconds.
KeepaliveSpecifies the Gateway Signal Channel Keepalive Timer (in seconds.) This value applies to all signal channels. The value ranges from 1 to 65535 and the default value is 3 seconds.
RetrySpecifies the amount of time (in minutes) the SBC will continue to attempt to recover a GW Signaling Link as long as there are stable calls up. The value ranges from 1 to 65535 and the default value is 60 seconds.
IdleSpecifies the amount of time (in hours) a GW Signaling Link May be idle before it is taken down. If set to 0, the link will not be taken down. The value ranges from 0 to 65535 and the default value is 0.
Cong Rel Delay
Specifies the amount of time (in seconds) that a call which is rejected due to congestion will be delayed before the release is issued. Prevents re-attempts from causing overload conditions. The value ranges from 0 to 5 and the default value is 0.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 