DO NOT SHARE THESE DOCS WITH CUSTOMERS!
This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.
Use this object to configure H.323 Signaling Ports.
Each signaling port within an Address Context must use a unique IP address and port number combination.
The SBC 5210 and SBC 7000 systems support creating IP Interface Groups containing sets of IP interfaces that are not "processor friendly" (i.e. carried on physical Ethernet ports served by separate processors). However, restrictions exist regarding the usage of such Interface Groups.
(This ability does not apply to the SBC 5110 and 5400 systems which have only two physical media ports. IP interfaces from the two physical ports may be configured within the same IP Interface Groups without restrictions.)
For complete details, refer to Configuring IP Interface Groups and Interfaces.
% set addressContext <name> zone <name> h323SigPort <#> action <dryup | force> dryUpTimeout <0-1440> dscpValue <#> h225IpAddress <IPv4 address> h245IpAddress <IPv4 address> ipInterfaceGroupName <name> mode <inService | outOfService> portNumber <#> state <disabled | enabled>
// Mandatory parameters:
h323SigPort <index #> action <force | dryUp> dscpValue <0-63> h225IpAddress <ip address> ipInterfaceGroupName <name> mode <inService | outOfService> portNumber <1-65535> state <disabled | enabled>
// Non-mandatory parameters:
dryUpTimeout <0-1440> h245IpAddress <ip address>