DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.8.1.2.1.12.0.3

Description

This alarm indicates CRC error rate exceeds the configurable "setThreshold" for the specified Ethernet port.

Repetition

None.

Event Codes

sonusEthErrorType

sonusEthInterfaceType

Instance Fields

None.

Action

Examine the proper functioning of the network interface element that reports an error.

Impact

Communication integrity of the network interface maybe compromised or becomes unreliable.

Clearing

Automatic;  sonusSystemSecurityEthernetClearNotification