DO NOT SHARE THESE DOCS WITH CUSTOMERS!
This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.
Type: MAJOR
Object ID | 1.3.6.1.4.1.2879.2.10.1.1.21.0.10 |
Description | Indicates a node switchover is initiating as the system is unable to recover from port toggling. |
Repetition | None |
Event Codes |
|
Instance Fields | None |
Action | Node switchover is initiated. After the switchover, examine the health of the failed links of the current standby node, and fix them. To check the current status of the links, use the following CLI commands: show table addressContext <ACName> linkDetectionGroup show table addressContext <ACName> linkDetectionGroup <LDGName> linkMonitorStatus show table system ethernetPort portMonitorStatus Refer to the CLI pages Link Detection Group - CLI and Show Table System, for more details. |
Impact | Node switchover to the standby server occurs. |
Clearing | Manual |