DO NOT SHARE THESE DOCS WITH CUSTOMERS!

This is an LA release that will only be provided to a select number of PLM-sanctioned customers (PDFs only). Contact PLM for details.


Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.4.0.1

Description

This alarm indicates that call admission into the SBC Core server has been suspended. Information provided by this trap includes one of the following reasons why call admission is suspended:

  • Critical system overload
  • NTP timing not available following system initialization
  • Transient call cleanup following a switchover

Repetition

None

Event Codes

sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId
sonusAlarmTime
sonusAlarmDescription
sonusCallAdmissionChangeReason

Instance Fields

sonusCallAdmissionChangeReason

Action

Investigate based on the reason for the suspension, and correct problem.

Impact

No calls are admitted to the system or the affected server card while call admission is suspended.

For the case where a valid NTP source is not available following system initialization, call admission is suspended until a valid NTP time reference is obtained. This action is taken to ensure that accounting records may be generated with the correct time of day. For other cases, call admission is suspended for a short time and the condition does not require any operator action.

For example, during card failover processing, call admission is suspended briefly as the standby card transitions to the active state. Call admission is resumed as soon as the card has completed the transition and is ready to accept new call arrivals.

Clearing

Automatic, sonusSbxNodeResourcesCallAdmissionEnabledNotification