Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.25.0.8
DescriptionThis alarm indicates that the specified IPv6 Control Channel Link to a remote D-SBC node has closed.
RepetitionOccurs when the D-SBC control channel link open request is sent. Alarm data includes the remote IP and port.
Event Codes

sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId
sonusAlarmTime
sonusAlarmDescription
sonusDsbcRemoteDsbc6Addr
sonusDsbcCloseReasonCode

  • administratorInitiatedClose(1)
  • closeRequestReceivedFromRemote(2)
  • remoteNotResponding(3)
  • internalError(4)
  • configError(5)
  • recvCallSigReqFromUnknownGw(6)
  • socketErrNetworkDown(7)
  • socketErrNetworkUnreachable(8)
  • socketErrNetworkReset(9)
  • socketErrSoftwareConnectionAbort(10)
  • socketErrConnectionResetByPeer(11)
  • socketErrNoBufferSpaceAvail(12)
  • socketErrAlreadyConnected(13)
  • socketErrNotConnected(14)
  • socketErrCantSendAfterShutdown(15)
  • socketErrTooManyReferences(16)
  • socketErrConnectionTimedOut(17)
  • socketErrUnknown(18)
  • recvDuplicateLinkOpenReq(19)
  • socketErrExceptionEvent(20)
  • linkXmtCongestion(21)
  • openNackReceivedFromRemote(22)
  • idleTimeOut(23)
Instance FieldssonusDsbcRemoteDsbc6Addr
sonusDsbcCloseReasonCode
ActionCheck connectivity for any link issues.
Impact

This condition may impact calls if the control channel link does not re-establish.    

ClearingManual

  • No labels