From SBC1 onwards, to comply with RFC 6337 standards, flag onlySendSubsequent18xSdpIfUnreliabl
e is enabled to allow the SBC to include the SDP in subsequent 18x response message after a unreliable provisional response is sent.
Command Syntax
% set addressContext default zone <zone_name> sipTrunkGroup <siptrunkgroup_name> signaling onlySendSubsequent18xSdpIfUnreliable <enabled | disabled>
Command Parameters
onlySendSubsequent18xSdpIfUnreliable
Parameter | Description |
---|
| Enable this flag to allow the SBC to send SDP in subsequent unreliable 18x messages. Once the reliable response is sent, the SBC stops sending the SDPs. This behavior is RFC 6377 compliant.
When disabled, the SBC sends the SDP in subsequent 18x messages, regardless of their reliability. This is the same behaviour as releases prior to 8.2.0
For more information, refer to Ingress IP Attributes - SIP - CLI The options include: disabled (default) enabled
|
Command Example
% set addressContext default zone ZONE_INGRESS sipTrunkGroup TG_INGRESS signaling onlySendSubsequent18xSdpIfUnreliable enabled