You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
Version 1
Next »
The criteria for recording calls using the Media Capture Tool (MCT) is configured in PSX and when a call meets the criteria, PSX indicates the need for media forking in the Policy Response to
Unable to show "metadata-from": No such page "_space_variables"
. This feature allows you to configure the Monitor Endpoint server where the captured media is sent.
Command Syntax
% set global monitorEndpoint mct <monitor endpoint name>
ipAddress <intfc_ip_address>
portNumber <sip_signaling_port_#>
state <disabled|enabled>
trunkGroup <TG_name>
Command Parameters
Global Monitor Endpoint Parameters
Parameter | Length/Range | Description |
---|
monitorEndpoint
| N/A | Use this control to configure the monitor endpoint. mct <monitor endpoint name> ipAddress – Logical IP address of the interface.portNumber – UDP/TCP port number of SIP signaling port. (default = 5060).state – Administrative state of MCT. Changes can only be made when state is disabled, and are applied upon next enable action.disabled (default)enabled
trunkGroup – Name of trunkgroup used by MCT.
|
Parameter | Length/Range | Description |
---|
monitorEndpoint
| N/A | Use this control to configure the monitor endpoint. mct <monitor endpoint name> ipAddress – Logical IP address of the interface.portNumber – UDP/TCP port number of SIP signaling port. (default = 5060).state – Administrative state of MCT. Changes can only be made when state is disabled, and are applied upon next enable action.disabled (default)enabled
trunkGroup – Name of trunkgroup used by MCT.
|
Command Example
% set global monitorEndpoint mct <MCT-1> ipAddress <10.22.33.44> portNumber <5060> state enabled> trunkGroup <SIPTX-EAST>