You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »

 

 

In this section:

Specifies various digit detection attributes for Digit Profile.

To View and Edit Dtmf Detect

On SBC main screen, go to Configuration > Profile Management > Category: Digit Profiles > Digit Profiles > Dtmf Detect.

Select the desired Digit Profile from the drop-down list to view its respective Dtmf Detect parameters.

The Dtmf Detect window is displayed.

Profile Management - Digit Profiles - Dtmf Detect

 

The following fields are displayed:

Dtmf Detect Parameters

 
Parameter Description
Min Power

Specifies minimum power level in dBm required for digit detection. The value ranges from -45 to -25 dBm and the default value is -45.

Min On Duration

Specifies minimum tone duration in milliseconds required for digit detection. The value must be increments of 5ms. The value ranges from 25 to 80 milliseconds and the default value is 35 milliseconds.

Min Off Duration

Specifies minimum tone duration in milliseconds required for digit detection. The value must in increments of 5ms. The value ranges from 25 to 80 milliseconds and the default value is 25 milliseconds.

Frequency Range

Specifies frequency tolerances for digit detection. The value represents accept and reject ranges. Frequencies detected within the accept range will result in digit detection. Frequencies detected outside the reject range will not result in digit detection. The options are:

  • narrow
  • medium
  • wide
  • wider
Twist Cutoff

Specifies the ratio of high group power to low. Twist ratios below the twist cutoff will result in digit detection. Twist ratios above the twist cutoff will result in digit rejection. The value ranges from 4 to 12 dB and the default value is 8 dB.

This parameter is used only for DTMF digit detection.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

 

  • No labels