You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

In this section:

Sonus-provided SFP modules must be used to guarantee proper operation of the external ports. Failure to follow this recommendation may cause permanent damage to the system.

1 Gb SFP Parts

The 

Unable to show "metadata-from": No such page "_space_variables"
supports the following Small Form-factor Pluggable (SFP) transceivers in all Management, Media, and HA ports. SFPs are Customer Replaceable Units (CRUs).

1Gb SFP Parts

Transceiver TypeProduct CodeDescription
CopperSBC-SFPCOPPER-1GGIGE, 1000 BASE-T SMALL FROM PLUGGABLE (SFP)
Must use one of the following:
 ManufacturerManufacturer Part Number
 AVAGO TECHNOLOGIESABCU-5710RZ-SN1
 AVAGO TECHNOLOGIESABCU-5740RZ-SN1
 BROADCOMABCU-5740RZ-SN1
 FINISARFCLF8521P2BTL-SS
Single-mode fiberSBC-SFPSM-1GGIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 10KM 1310NM, DMI
Must use one of the following:
 ManufacturerManufacturer Part Number
 AVAGO TECHNOLOGIESAFCT-5715PZ-SN1
 BROADCOMAFCT-5715PZ-SN1
 FINISARFTLF1318P2BTL-SS
 FINISARFTLF1318P3BTL-SS
Multi-mode fiberSBC-5400-SFPMMGIG-E, MULTIMODE, FIBER OPTIC TRANCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 300M
Must use one of the following:
 ManufacturerManufacturer Part Number
 AVAGO TECHNOLOGIESAFBR-5715PZ-SN1
 BROADCOMAFBR-5715PZ-SN1
 FINISARFTLF8519P2BNL-SS
 FINISARFTLF8519P3BNL-SS

10 Gb SFP Parts

Optionally, Pkt0 can be used as a single 10 Gb port, with the remaining MEDIA ports empty. The parts for the 10 Gb SFPs are:

10Gb SFP Parts

Transceiver TypeProduct CodeDescription
Single-mode fiberSBC-SFPSM-10G10.3 GB/S, SINGLE MODE, FIBER OPTIC XCVR, LC, SFP, 10KM 1310NM, DM
Must use one of the following:
 ManufacturerManufacturer Part Number
 AVAGO TECHNOLOGIESAFCT-709SMZ-SN1
 AVAGO TECHNOLOGIESAFCT-739SMZ-SN1
 BROADCOMAFCT-739SMZ-SN1
 BROADCOMAFCT-709SMZ-SN1
 FINISARFTLX1471D3BCL-SS
Multi-mode fiberSBC-SFPMM-10G10.3 GB/S, MULTIMODE, FIBER OPTIC XCVR, LC, SFP, 300M 850NM, DMI GIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE
Must use one of the following:
 ManufacturerManufacturer Part Number
 AVAGO TECHNOLOGIESAFBR-709SMZ-SN1
 BROADCOMAFBR-709SMZ-SN1
 FINISARFTLX8574D3BCL-SS
 FINISARFTLX8571D3BCL-SS
To replace SFPs, use the procedures from the section Replacing the SFP.

SFP Ports

Parts and Tools Required

  • Electrostatic discharge (ESD) strap
  • Replacement SFP transceivers.

To prevent damage from electrostatic discharge, an ESD strap is provided in the accessory kit. Refer to Connecting ESD Wrist Strap to install it.

Replacing the SFP

Perform the following procedure to replace the SFP:

  1. Attach an ESD wrist strap using the ESD grounding point on the rear panel of the chassis (refer to Connecting ESD Wrist Strap for details).
  2. Disconnect the fiber optic and/or Cat 5 cables, as appropriate, from media ports (Pkt0/1/2/3) and HA ports (HA 0-1).

  3. Disengage the SFP transceiver from

    Unable to show "metadata-from": No such page "_space_variables"
    . The method used to disengage the SFP transceiver will vary according to the manufacturer. For example, hold the wire latch and move it downwards to the horizontal position and pull it outwards, as shown below.

     

    Removing SFP

  4. Insert the Sonus-approved SFP transceiver into the desired socket and ensure that the latch mechanism engages.

  5. Reconnect the fiber optic and/or Cat 5 cables, as appropriate, to media and HA ports.
  6. Verify LEDs above the part are flashing indicating link status and data activity.
  7. Verify port functionality using the application.

CRU Storage

All 

Unable to show "metadata-from": No such page "_space_variables"
CRUs are shipped in electrostatic discharge bags and should be handled using appropriate ESD precautions.

The storage environment for these CRUs are:

  • Humidity must be less than 95% (non-condensing).
  • Temperature must be between -40C and +70C.

The ESD Susceptibility symbol warns of the presence of Sonus devices susceptible to electrostatic discharge. Do not handle equipment without wearing a properly grounded ESD wrist strap.

  • No labels