The IP Policing Alarm Profile specifies the parameters to determine when alarms associated with IP policing are generated and cleared.
To View Ip Policing Alarm Profile
On SBC main screen, go to Configuration > Profile Management > Category: System Profiles > Ip Policing Alarm Profile.
The Ip Policing Alarm Profile window is displayed.
Profile Management - System Profiles - Ip Policing Alarm Profile
To Edit Ip Policing Alarm Profile
To edit any of the Ip Policing Alarm Profile in the list, click the radio button next to the specific Ip Policing Alarm Profile name.
Profile Management - System Profiles - Ip Policing Alarm Profile Highlighted
The Edit Selected Ip Policing Alarm Profile window is displayed below.
Profile Management - System Profiles - Ip Policing Alarm Profile Edit Window
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.
To Create Ip Policing Alarm Profile
To create a new Ip Policing Alarm Profile, click New Ip Policing Alarm Profile tab on the Ip Policing Alarm Profile List panel.
Profile Management - System Profiles - Ip Policing Alarm Profile Fields
The Create New Ip Policing Alarm Profile window is displayed.
Profile Management - System Profiles - Ip Policing Alarm Profile Create Window
The following fields are displayed:
IP Policing Alarm Profile Parameters
Parameter | Description |
---|
Name
| Specify the name of the IP Policing Alarm. |
Index
| A unique identifier |
State
| Administrative state of IP Policing alarm. |
Bad Ethernet IP Header Set Threshold
| Specifies the threshold for the bad ethernet IP header policer discard rate which may set an alarm. The default value is 100. |
Bad Ethernet IP Header Clear Threshold
| Specifies the threshold for the bad Ethernet IP header policer discard rate which may clear an alarm. The default value is 20. |
Bad Ethernet IP Header Set Duration
| Specifies the duration (in seconds) that the bad ethernet IP header policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3. |
Bad Ethernet IP Header Clear Duration
| Specifies the duration (in seconds) that the bad Ethernet IP header policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3. |
Arp Set Threshold
| Specifies the duration (in seconds) that the bad Ethernet IP header policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 100. |
Arp Clear Threshold
| Specifies the threshold for the ARP policer discard rate which may clear an alarm. The default value is 20. |
Arp Set Duration
| Specifies the duration (in seconds) that the ARP policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3. |
Arp Clear Duration
| Specifies the duration (in seconds) that the ARP policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3. |
U Flow Set Threshold
| Specifies the threshold for the micro flow policer discard rate which may set an alarm. The default value is 100. |
U Flow Clear Threshold
| Specifies the threshold for the micro flow policer discard rate which may clear an alarm. The default value is 20. |
U Flow Set Duration
| Specifies the duration (in seconds) that the micro flow policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3. |
U Flow Clear Duration
| Specifies the duration (in seconds) that the micro flow policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3. |
Acl Set Threshold
| Specifies the threshold for the access control list policer discard rate which may set an alarm. The default value is 100. |
Acl Clear Threshold
| Specifies the duration (in seconds) that the access control list policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3. |
Acl Set Duration
| Specifies the duration (in seconds) that the access control list policer discard rate must be at or above its set threshold before an alarm is set. A value of 0 sets the alarm immediately. |
Acl Clear Duration
| Specifies the duration (in seconds) that the access control list policer discard rate must be at or below its clear threshold before an alarm is cleared. A value of 0 clears the alarm immediately. |
Aggregarte Set Threshold
| Specifies the threshold for the aggregate policer discard rate which may set an alarm. The default value is 100. |
Aggregarte Clear Threshold
| Specifies the threshold for the aggregate policer discard rate which may clear an alarm. The default value is 20. |
Aggregate Set Duration
| Specifies the duration (in seconds) that the aggregate policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3. |
Aggregate Clear Duration
| Specifies the duration (in seconds) that the aggregate policer discard rate must be at or below its clear threshold before an alarm is cleared. A value of 0 clears the alarm immediately. |
IP Sec Decrypt Set Threshold
| Specifies the threshold for the IPSEC decrypt policer discard rate which may set an alarm. The default value is 100. |
IP Sec Decrypt Clear Threshold
| Specifies the threshold for the IPSEC decrypt policer discard rate which may clear an alarm. The default value is 20. |
IP Sec Decrypt Set Duration
| Specifies the duration (in seconds) that the IPSEC decrypt policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3. |
IP Sec Decrypt Clear Duration
| Specifies the duration (in seconds) that the IPSEC decrypt policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3. |
Media Set Threshold
| Specifies the threshold for the media policer discard rate which may set an alarm. The default value is 100. |
Media Clear Threshold
| Specifies the threshold for the media policer discard rate which may clear an alarm. The default value is 20. |
Media Set Duration
| Specifies the duration (in seconds) that the media policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3. |
Media Clear Duration
| Specifies the duration (in seconds) that the media policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3. |
Rogue Media Set Threshold
| Specifies the threshold for the rogue media policer discard rate which may set an alarm. The default value is 100. |
Rogue Media Clear Threshold
| Specifies the threshold for the rogue media policer discard rate which may clear an alarm. The default value is 20. |
Rogue Media Set Duration
| Specifies the duration (in seconds) that the rogue media policer discard rate must be at or above its set threshold before an alarm is set. The default value is 3. |
Rogue Media Clear Duration
| Specifies the duration (in seconds) that the rogue media policer discard rate must be at or below its clear threshold before an alarm is cleared. The default value is 3. |
Discard Rule Set Threshold
| Specifies the threshold for the discard rule discard rate which may set an alarm. The default value is 20. |
Discard Rule Clear Threshold
| Specifies the threshold for the discard rule discard rate which may clear an alarm. The default value is 10. |
Discard Rule Set Duration
| Specifies the duration (in seconds) that the discard rule discard rate must be at or above its set threshold before an alarm is set. A value of 0 sets the alarm immediately. |
Discard Rule Clear Duration
| Specifies the duration (in seconds) that the discard rule discard rate must be at or below its clear threshold before an alarm is cleared. A value of 0 clears the alarm immediately. |
To Copy Ip Policing Alarm Profile
To copy any of the created Ip Policing Alarm Profile and to make any minor changes, click the radio button next to the specific Ip Policing Alarm Profile to highlight the row.
Profile Management - System Profiles - Ip Policing Alarm Profile Highlighted
Click Copy Ip Policing Alarm Profile tab on the Ip Policing Alarm Profile List panel.
Profile Management - System Profiles - Ip Policing Alarm Profile Fields
The Copy Selected Ip Policing Alarm Profile window is displayed along with the field details which can be edited.
Profile Management - System Profiles - Ip Policing Alarm Profile Copy Window
Make the required changes to the required fields and click Save to save the changes. The copied Ip Policing Alarm Profile is displayed at the bottom of the original Ip Policing Alarm Profile in the Ip Policing Alarm Profile List panel.
To Delete Ip Policing Alarm Profile
To delete any of the created Ip Policing Alarm Profile, click the radio button next to the specific Ip Policing Alarm Profile which you want to delete.
Profile Management - System Profiles - Ip Policing Alarm Profile Highlighted
Click Delete at the end of the highlighted row. A delete confirmation message appears seeking your decision.
Profile Management - System Profiles - Ip Policing Alarm Profile Delete Confirmation
Click OK to remove the specific Ip Policing Alarm Profile from the list.