You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 5
Next »
RAMP support only
Beginning with SBC Core release 12.0, the SBC interoperates with the Ribbon Application Management Platform (RAMP), replacing the Insight EMS.
However, the EMA, CLI and API will continue to include EMS-labeled parameters and screens to facilitate SBC migrations from older releases. Accordingly, any references to "EMS" in this documentation apply to the RAMP platform.
Warning
Clear the upgrade directory from both servers before reattempting further upgrades using the command rm -fr /var/log/sonus/upgrade/*
under all the following conditions:
- There is a need to revert the upgraded server after a single server upgrade while the peer is still on an older version.
- A revert will be performed by doing a re-ISO.
This section describes the different methods to upgrade the
Unable to show "metadata-from": No such page "_space_variables"
application.
When an
Unable to show "metadata-from": No such page "_space_variables"
upgrade is available, the software is posted on the Ribbon Support Portal. Refer to
Downloading Software from the Ribbon Support Portal for more information.
Prerequisites
Prior to performing an upgrade on the
Unable to show "metadata-from": No such page "_space_variables"
, ensure the following activities are accomplished.
Unable to show "metadata-from": No such page "_space_variables"
(in general)
- Before upgrading the ConnexIP OS, firmware, and the
Unable to show "metadata-from": No such page "_space_variables"
application, you must first save the configuration in case you encounter any issues during the upgrade. Before upgrading the application, upgrade the SBC firmware to the latest version on both the active and standby SBCs for an HA pair.
Unable to show "metadata-from": No such page "_space_variables"
Live Software Upgrade (LSWU)
LSWU allows a user to upgrade the
Unable to show "metadata-from": No such page "_space_variables"
application software on HA pairs without impacting service (dropping calls). This is mainly recommended for HA SBC systems. You can also perform a LSWU on the Unable to show "metadata-from": No such page "_space_variables"
EMA and in Unable to show "metadata-from": No such page "_space_variables"
EMA Platform Mode. Refer to Live Software Upgrade using CLI and System Administration - Software Install-Upgrade for more information.Non-Live Software Upgrade (Non-LSWU)
The non-LSWU upgrade process requires taking the SBC system offline to perform an application upgrade. This refers to upgrading the
Unable to show "metadata-from": No such page "_space_variables"
application in a standalone or HA configuration using EMA Platform Mode. Refer to Upgrading SBC Application using EMA Platform Mode for more information.
On Unable to show "metadata-from": No such page "_space_variables"
7000 setup, the active node takes more than expected the time for the services to come up after an upgrade to V12.00.00R000 from 11.1.0x. Before performing an upgrade from 11.1.0x, apply the following steps:
- Confirm that the cnixpmadmin password is not default by running the following command as root on the active and standby nodes:
$ENCRYPTED_STORE_SH cnxipmadmin
NOTE: The command must not show the default password "Cnx1PmAdm1n"
- If the password is still default, randomize the password by running the following command as root on the active node:
$CHANGE_DEFAULT_PASSWDS_SH
- Check the cnxipmadmin password is updated to random on the active and standby node by running the following command:
$ENCRYPTED_STORE_SH cnxipmadmin