You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

Type: MAJOR

Object ID1.3.6.1.4.1.2879.2.10.1.1.25.0.26
DescriptionThis alarm indicates that an M-SBC node allocation failure occurred (IPv6 network).
RepetitionThis alarm repeats until the M-SBC is able to allocate the resources successfully.
Objects
  • sonusAlarmNodeID
  • sonusAlarmLevel
  • sonusAlarmSequenceId
  • sonusAlarmTime
  • sonusAlarmDescription
  • sonusDsbcAllocFailuresCount
  • sonusDsbcRemoteDsbc6Addr
ActionCalls offered to the M-SBC fail.
ImpactThe M-SBC node rejects calls.
Clearing

Automatic

  • sonusSbxDsbcNodeAllocationFailureClear

  • No labels